TM 5-3895-373-34
2.44
REPAIR STACK VALVE AND STACK VALVE WIRING HARNESS - Continued.
B.
CLEAN - Continued.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to the
skin, eyes, and respiratory system.
Avoid
prolonged
exposure.
Eye
protection and rubber gloves must be
worn when working with hydraulic oil.
5.
SUBMERGE MANIFOLDS, VALVE SPOOL,
SAFETY RELIEF VALVE, AND/OR CHECK VALVE
IN CLEAN HYDRAULIC OIL AFTER DRYING.
COVER CONTAINER UNTIL COMPONENTS
ARE READY TO BE INSTALLED.
C.
INSTALL.
1.
INSTALL
VALVE
ELECTRICAL
COIL
CONNECTOR
ON
STACK
VALVE
WIRING
HARNESS.
a.
Lubricate first 2 in. (76 mm) of wiring harness
sleeving with petrolatum. Slide packing nut (52),
packing retainer (55), and packing (54) onto
wiring harness.
b.
Insert harness wiring through wiring port of
connector body (51). Loosen crimping screws in
contact housing (53).
c.
Insert stripped harness lead ends onto mating
terminals per lead wire markings made during
removal. Tighten lead wire crimping screws.
Electrical insulating varnish fumes can
be harmful if inhaled. Use only in well
ventilated
area.
Avoid
prolonged
exposure
to
fumes.
If
personnel
become dizzy or drowsy during use, get
immediate medical attention.
d.
Coat wiring terminals with electrical insulating
varnish. Allow 30 minutes for varnish to air dry
before handling contact housing (53).
GO TO NEXT PAGE
2-612