TM 5-3895-373-34
A.
REMOVE - Continued.
NOTE
Most of the following procedures will
show stack valve wiring harnesses
removed for clarity of view.
For
maintenance
purposes,
remove
stack valve wiring harnesses only as
needed to replace damaged harness,
stack valve, or stack valve components.
1.
REMOVE STACK VALVE WIRING HARNESSES.
a.
Loosen screws (1) and unplug electrical coil
connectors (2).
b.
Remove moisture seal (3). If moisture seal is
damaged, discard it. Otherwise, retain moisture
seal for reassembly.
c.
Remove stack valve wiring harnesses (4 and 5).
2.
REMOVE ELECTRICAL COIL.
a.
Remove hex nut (6).
b.
Remove electrical coil (7) from stack valve.
GO TO NEXT PAGE
2-605