TM 5-3895-373-34
A.
REMOVE - Continued.
5.
REMOVE CHECK VALVE.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to the
skin, eyes, and respiratory system.
Avoid prolonged exposure. Eye
protection and rubber gloves must be
worn when working with hydraulic oil.
a.
Position machinery wiping towel to collect
residual hydraulic oil in open check valve port.
b.
Loosen and remove check valve (13 or 14). Cap
off open valve ports with protective caps.
c.
If saturated, dispose of machinery wiping towel
in accordance with local procedures.
GO TO NEXT PAGE
2-607