TM 5-3895-373-34
C.
CLEAN Continued.
Compressed air used for cleaning
purposes will not exceed 30 psi (207
kPa). Use only with effective chip
guarding
and
personal
protective
equipment (goggles/face shield and
gloves). Failure to take proper
precautions may result in severe
injury or loss of vision.
If replacing gears with new gears,
preservative coating on new gears
must be thoroughly cleaned away
with cleaning solvent. Failure to
clean replacement gears may cause
pump failure.
b.
Use
a
maximum
of
30
psi
(207
kPa)
compressed air to remove foreign material from
front flange, pump housing, rear cover, and
gears.
c.
Dry all parts with a clean, lint-free cloth.
2.
CLEAN SCREW THREADS.
Thread locking compound solvent
can cause eye damage. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If solvent contacts
eyes, flush eyes with water and get
immediate medical attention.
a.
Clean
screw
threads
with
thread
locking
compound solvent.
b.
Dry fasteners with a cleaning cloth.
GO TO NEXT PAGE
2-591