TM 5-3895-373-34
2.42
REPLACE/REPAIR AUXILIARY PUMP - Continued.
F.
INSTALL Continued.
3.
CONNECT OUTLET HOSES AND SUCTION
HOSE TO AUXILIARY PUMP.
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Coat exposed threads of straight adapter (6 and
8) with hydraulic fitting sealant. Install and
tighten outlet hoses (2 and 3).
b.
Coat exposed threads of straight adapter (4) with
hydraulic fitting sealant. Using combination
wrench, install and tighten suction hose (1).
NOTE
FOLLOW-ON-TASKS:
Prime hydraulic pump per paragraph 2.54.
Install right access cover per TM 5-3895-373-10.
Close right access door per TM 5-3895-373-10.
Close front top right access door per TM 5-3895-373-10.
END OF TASK
2-582