TM 5-3895-373-342.42REPLACE/REPAIR AUXILIARY PUMP - Continued.F. INSTALL.1.INSTALL HYDRAULIC FI’I-LINGS ON AUXILIARYPUMP.a.Remove protective caps.b.Install lockwashers (11) onto cap screws (10).Sealing compound can cause eye damage.Wear safety goggles/glasses when using.Avoid contact with eyes. If compoundcontacts eyes, flush eyes with water and getimmediate medical attention.c.Coat gasket (13) with a thin coat of sealingcompound.d.Install gasket (13) and port adapter (12).e.Install cap screws (10). Tighten to 14 lb-ft (19N.m).f.Lubricate preformed packings (5, 7, and 9) with, petrolatum.Be careful not to damage preformedpacking when sliding over threads.Sharp edges of threads can cut ordamage preformed packing.Damaged packing will causeleakage and affect performance.NOTEWhen installing hydraulic fittings onright auxiliary pump, an elbow will beinstalled in place of straight adapter(4).g.Using combination wrench, install preformedpacking (5) onto straight adapter (4). Installstraight adapter into port adapter (12).NOTEWhen installing elbow in place ofstraight adapter (4), orient elbow topoint toward backplate assembly.h.Install preformed packing (7) onto straightadapter (6). Install straight adapter into pumphousing.i.Install preformed packing (9) onto straightadapter (8). Install straight adapter into pumphousing.GO TO NEXT PAGE2-580