TM 5-3895-373-34A.REMOVE - Continued.b.Remove socket head cap screws (4) from pumppilot control valve (2).c.Remove pump pilot control valve (2).Hydraulic oil can be moderately flammable andcan be an irritant to the skin, eyes, andrespiratory system. Avoid prolonged exposure.Eye protection and rubber gloves must be wornwhen working with hydraulic oil.d.Use a cleaning cloth to clean up any excesshydraulic oil.2.REMOVE PREFORMED PACKINGS FROM PUMPPILOT CONTROL VALVE.Use caution when removing seals andpreformed packings. Do not use excessive forcewhen removing seals and preformed packings.Use an o-ring tool to remove seals andpreformed packings. Scratched or dented sealgrooves can cause valve leakage.a.Use an o-ring tool and remove preformedpackings (5) from pump pilot control valve (2).Discard preformed packings.b.Use an o-ring tool and remove preformedpacking (6) from screen (7). Discard preformedpacking.GO TO NEXT PAGE2-439
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business