TM 5-3895-373-34
A.
REMOVE - Continued.
b.
Remove socket head cap screws (4) from pump
pilot control valve (2).
c.
Remove pump pilot control valve (2).
Hydraulic oil can be moderately flammable and
can be an irritant to the skin, eyes, and
respiratory system. Avoid prolonged exposure.
Eye protection and rubber gloves must be worn
when working with hydraulic oil.
d.
Use a cleaning cloth to clean up any excess
hydraulic oil.
2.
REMOVE PREFORMED PACKINGS FROM PUMP
PILOT CONTROL VALVE.
Use
caution
when
removing
seals
and
preformed packings. Do not use excessive force
when removing seals and preformed packings.
Use an o-ring tool to remove seals and
preformed packings. Scratched or dented seal
grooves can cause valve leakage.
a.
Use an o-ring tool and remove preformed
packings (5) from pump pilot control valve (2).
Discard preformed packings.
b.
Use an o-ring tool and remove preformed
packing (6) from screen (7). Discard preformed
packing.
GO TO NEXT PAGE
2-439