TM 5-3895-373-34
G.
ADJUST - Continued.
j.
Remove pressure gauges from servo ports (132
and 133).
k.
Install and tighten plugs (130 and 131).
l.
Apply electrical insulating compound to male
terminals of harness electrical connectors (2).
m.
Connect pump pilot control valve electrical
connector (1) to harness electrical connector (2).
4.
REMOVE
CRIBBING
AND
LOWER
PAVING
MACHINE PER TM 5-3895-373-20.
NOTE
FOLLOW-ON-TASKS: Adjust/calibrate control handle per TM 5-3895-373-20.
Install right access cover per TM 5-3895-373-10.
Close right access door per TM 5-3895-373-10.
Close front top right access door per TM 5-3895-373-10.
END OF TASK
2-437