TM 5-3895-373-34
B.
DISASSEMBLE Continued.
8.
REMOVE REMOTE FILTER ADAPTER.
a.
Remove hex head cap screws (73) and remote
filter adapter (74).
b.
Use an o-ring tool to remove filter adapter seal
(75). Discard filter adapter plain seal.
9.
REMOVE
ELECTRONIC
DISPLACEMENT
CONTROL.
NOTE
If pump pilot control valve is being
removed, refer to paragraph 2.31.
a.
Remove hex head cap screws (76 and 77) and
electronic displacement control (78).
Use caution when removing preformed
packings
and
packing
retainers.
Scratched or dented seal grooves can
cause bypass leakage. Do not use
excessive force to remove preformed
packings and packing retainers. Use an
o-ring
tool
to
remove
preformed
packings and packing retainers.
b.
Use an o-ring tool to remove
preformed
packings (79, 80, and 81) from electronic
displacement
control.
Discard
preformed
packings.
c.
Remove spool (82) by carefully prying out with a
thin, flat-blade screwdriver.
GO TO NEXT PAGE
2-403