TM 5-3895-373-34B.DISASSEMBLE Continued.8.REMOVE REMOTE FILTER ADAPTER.a.Remove hex head cap screws (73) and remotefilter adapter (74).b.Use an o-ring tool to remove filter adapter seal(75). Discard filter adapter plain seal.9.REMOVE ELECTRONIC DISPLACEMENTCONTROL.NOTEIf pump pilot control valve is beingremoved, refer to paragraph 2.31.a.Remove hex head cap screws (76 and 77) andelectronic displacement control (78).Use caution when removing preformedpackings and packing retainers.Scratched or dented seal grooves cancause bypass leakage. Do not useexcessive force to remove preformedpackings and packing retainers. Use ano-ring tool to remove preformedpackings and packing retainers.b.Use an o-ring tool to remove preformedpackings (79, 80, and 81) from electronicdisplacement control. Discard preformedpackings.c.Remove spool (82) by carefully prying out with athin, flat-blade screwdriver.GO TO NEXT PAGE2-403