TM 5-3895-373-34
2.25
REPAIR STARTER ASSEMBLY - Continued
F.
TEST.
1.
USE AN AUTOMOTIVE AND GENERATOR TEST STAND TO TEST STARTER FOR THE FOLLOWING
PARAMETERS OF OPERATION.
No-Load Test (includes solenoid current)
Volts
Min. Amps
Max. Amps
Min. RPM
Max. RPM
20
75
90
3600
5400
2.
USE AN AUTOMOTIVE AND GENERATOR TEST STAND TO TEST SOLENOID FOR THE FOLLOWING
PARAMETERS OF OPERATION.
Current Consumption (rated @ 24V)
Pull-in Winding
Hold-in Winding
Amps
Volts
Ohms
Amps
Volts
Ohms
100- 125
20
0.16/0.20
12- 14
20
1.45/1.65
NOTE: Resistance for test between solenoid terminals and solenoid casing shall not exceed 1.75 ohms.
NOTE
FOLLOW-ON-TASK: Install starter per TM 5-3895-373-10.
END OF TASK
2-352