TM 5-3895-373-34
2.69
REPLACE/REPAIR AUGER/CONVEYOR MOTOR AND DRIVE SPROCKET WHEEL - Continued.
E.
ASSEMBLE - Continued.
9.
INSTALL VALVE PLATE ONTO GEAR SET.
Hydraulic oil can be moderately flammable
and can be an irritant to the skin, eyes, and
respiratory system. Avoid prolonged expos-
ure. Eye protection and rubber gloves must
be worn when working with hydraulic oil.
a.
Apply clean hydraulic oil to preformed
packing (77) and install in groove of valve
plate (76).
b.
Align case drain port in valve plate (76) with
case drain port in gear set (79).
c.
Install valve plate (76) preformed packing
side onto gear set (79) using alignment
studs (97).
d.
Locate slot opening in valve plate (76)
which is in line with largest open pocket in
gear set (79).
10.
ALIGN AND INSTALL VALVE ONTO VALVE
PLATE.
a.
Locate any one of the side openings of
valve (75) that goes through to the face of
the valve.
b.
Line up this side opening with open slot of
valve plate (76) that is in line with the
largest open pocket of gear set (79)
marked with a grease pencil.
NOTE
Clockwise
rotation
of
valve
is
from
perspective of looking down at valve with
valve being at top of stacked components.
Ensure valve is rotated clockwise to align. If
valve is rotated counterclockwise motor will
run backward.
c.
Install valve (75) onto splined end of valve
drive shaft (78) against valve plate (76).
Rotate valve clockwise a distance of 1/2
spline tooth to engage spline teeth of valve
drive shaft.
GO TO NEXT PAGE
2-992