TM 5-3895-373-20
B.
INSTALL - Continued.
2.
INSTALL SIGHT LIQUID INDICATOR.
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Apply hydraulic fitting sealant to leading threads
of hex head cap screws (8).
Hydraulic oil can be moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
NOTE
Discard flat washers and hex nuts
supplied with sight liquid indicator.
Flat washers and hex nuts
are not used in this application.
b.
Lubricate preformed packing (10) with clean
hydraulic oil. Install preformed packing and sight
liquid indicator (9).
c.
Install hex head cap screws (8). Tighten evenly.
d.
Add oil to hydraulic reservoir until proper fluid
level is seen in the sight liquid indicator per TM
5-3895-373-10.
NOTE
FOLLOW-ON-TASKS:
Install right access cover per TM 5-3895-373-10.
Close right access door per TM 5-3895-373-10.
Close center top right access door per TM 5-3895-373-10.
END OF TASK