TM 5-3895-373-20
13.5.
REPLACE HIGH SPEED SHIFT AND BRAKE VALVE SOLENOID ASSEMBLIES AND STACK VALVE
ELECTRICAL COILS - Continued.
B.
INSTALL.
1.
INSTALL HIGH SPEED SHIFT VALVE
SOLENOID ASSEMBLY.
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
III cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Wipe off solenoid armature (2) with a lint-free
cloth and cleaning solvent.
b.
Locate preformed packings (18) in seal kit.
Lubricate preformed packings with petrolatum.
c.
Install preformed packings (18) on solenoid
assembly (3).
d.
Apply electrical insulating compound to terminal
pins of solenoid assembly (3).
e.
Plug solenoid assembly (3) into high speed shift
valve (4).
Do not overtighten plastic nut (1) on
solenoid
armature
(2).
Overtightening of plastic nut will strip
screw threads.
f.
Install plastic nut (1) onto solenoid armature (2).
Tighten by hand until snug, and then tighten an
additional 1/4 to 1/2 turn using an adjustable
wrench.
GO TO NEXT PAGE
13-30