TM 5-3895-373-20
13.3.
REPLACE SCREED LIFT CYLINDER - Continued.
NOTE
There is a left hand and a right hand screed lift cylinder
on the paving machine. This procedure refers to
replacing left hand screed lift cylinder. Procedure is
identical for right hand screed lift cylinder. Left hand
screed lift cylinder is shown in this procedure.
A.
REMOVE.
1.
DISCONNECT HYDRAULIC HOSES.
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective goggles
and gloves. Use only in a well ventilated
area. Avoid contact with skin, eyes, and
clothes, and do not breathe vapors.
Keep away from heat or flame. Never
smoke
when
using
solvent;
the
flashpoint for Type HI cleaning solvent is
200°F (93,3°C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using
cleaning solvent, immediately get fresh
air and medical help. If solvent contacts
skin or clothes, flush with cold water. If
solvent contacts eyes, flush eyes with
water and get immediate medical
attention.
Thoroughly clean hydraulic hoses and
fittings before disconnecting. Always
plug or cap off disconnected fittings to
prevent
intrusion
of
contaminants.
Failure to properly clean and cap off
connectors may result in hydraulic
system contamination and equipment
damage.
a. Use cleaning solvent and cleaning cloth to clean
around hydraulic hose (1 and 2) fittings on
screed lift cylinder (3).
b. Tag hydraulic hoses (1 and 2) for reinstallation.
GO TO NEXT PAGE
13-12