TM 5-3895-373-2013.2.REPLACE TOW POINT CYLINDER - Continued.B. INSTALL Continued.3. CONNECT HYDRAULIC HOSES.Hydraulic fitting sealant can cause eyedamage or skin irritation. Wash afterskin contact. Wear safetygoggles/glasseswhen using. Avoidcontact with eyes or skin. If sealantcontacts eyes, flush eyes with water andget immediate medical attention.a.Apply hydraulic fitting sealant to exposed threadsof elbows (10 and 15).b.Connect hydraulic hoses (I and 2) as tagged andtighten.c.Turn knob fully counterclockwise.NOTEFOLLOW-ON-TASK: Install left or right access cover per TM 5-3895-373-10.END OF TASK13-10