TM 5-3895-373-2011.4.REPLACE OPERATOR CONTROL CONSOLE SUPPORT FRAME - Continued.B.INSTALL - Continued.j.Unlock and slide operator control console(1) from side to side completely across theentire length of console mounting frame(11). Check to ensure that there is nobinding of movement and that a 1/4 in. (6,4mm) gap is maintained between roll stopbracket (24) on the control console and theconsole mounting frame.k.If adjustments to the 1/4 in. 6,4 mm) gapneed to be made, loosen self-locking hexnuts (12 and 16) and adjust positioning ofconsole mounting frame using a plastichammer.I.Snug self-locking hex nuts (12 and 16) andcheck operator control console (1)alignment with console mounting frame(11). Continue to adjust alignment until nobinding is found and a 1/4 in. (6,4 mm) gapis maintained for full travel of the controlconsole.m.Tighten self-locking hex nuts (12 and 16) to90 lb-ft (122 N•m).NOTEFOLLOW-ON-TASKS:Install left access cover per TM 5-3895-373-10.Install right access cover per TM 5-3895-373-10.END OF TASK11-40