TM 5-3895-373-207.10.REPLACE/REPAIR RELAY AND CIRCUIT BREAKER ASSEMBLY - Continued.A.DISASSEMBLE - Continued.4.REMOVE CIRCUIT BREAKER QUICKDISCONNECT TERMINALS AND BUSS BARFEMALE TERMINALS FROM CIRCUITBREAKER HOLDERS.a.Insert two flat-blade connector removal tools intocircuit breaker terminals (4).b.Press in on circuit breaker quick disconnectterminal (10) locking tabs to unlock terminal fromcircuit breaker holder (6).c.Pull circuit breaker quick disconnect terminals(10) from bottom of circuit breaker holder (6).All six tabs must be released beforeattempting removal of buss barfemale terminal. Do not attempt toremove buss bar female terminalwithout all six tabs released. Damageto buss bar female terminal mayresult from tabs not released prior toremoval.d.Repeat procedures to remove buss bar femaleterminal (11) from bottom of circuit breakerholder (6).5.REMOVE RELAY QUICK DISCONNECTTERMINALS FROM RELAY HOLDER.a.Insert flat-blade electrical connector removal toolinto relay terminal (7). Refer to illustration.b.Press in on relay quick disconnect terminal(12) locking tabs to unlock terminal from relayholder (9).c.Pull wire with relay quick disconnect terminals(12) from bottom of relay holder (9).NOTERelay and circuit breaker assemblycomponents cannot be repairedindividually. Once components areassembled they cannot be takenapart. Discard relay and circuitbreaker assembly if defective.6.DISCARD RELAY AND CIRCUIT BREAKERASSEMBLY IF DEFECTIVE OR DAMAGED.GO TO NEXT PAGE7-88