7.10.
REPLACE/REPAIR RELAY AND CIRCUIT BREAKER ASSEMBLY - Continued.
A.
DISASSEMBLE - Continued.
4.
REMOVE CIRCUIT BREAKER QUICK
DISCONNECT TERMINALS AND BUSS BAR
FEMALE
TERMINALS
FROM
CIRCUIT
BREAKER HOLDERS.
a.
Insert two flat-blade connector removal tools into
circuit breaker terminals (4).
b.
Press in on circuit breaker quick disconnect
terminal (10) locking tabs to unlock terminal from
circuit breaker holder (6).
c.
Pull circuit breaker quick disconnect terminals
(10) from bottom of circuit breaker holder (6).
All six tabs must be released before
attempting
removal
of
buss
bar
female terminal. Do not attempt to
remove buss bar female terminal
without all six tabs released. Damage
to buss bar female terminal may
result from tabs not released prior to
removal.
d.
Repeat procedures to remove buss bar female
terminal (11) from bottom of circuit breaker
holder (6).
5.
REMOVE RELAY QUICK DISCONNECT
TERMINALS FROM RELAY HOLDER.
a.
Insert flat-blade electrical connector removal tool
into relay terminal (7). Refer to illustration.
b.
Press in on relay quick disconnect terminal
(12) locking tabs to unlock terminal from relay
holder (9).
c.
Pull wire with relay quick disconnect terminals
(12) from bottom of relay holder (9).
NOTE
Relay and circuit breaker assembly
components
cannot
be
repaired
individually. Once components are
assembled they cannot be taken
apart. Discard relay and circuit
breaker assembly if defective.
6.
DISCARD RELAY AND CIRCUIT BREAKER
ASSEMBLY IF DEFECTIVE OR DAMAGED.
GO TO NEXT PAGE
7-88