TM 5-3895-373-20
B.
INSTALL Continued.
3.
INSTALL
LUG
TERMINALS
AND
RING
TERMINALS
ONTO
SWITCH
PANEL
COMPONENTS.
a.
Install ring terminals (3) onto emergency stop
switch. Secure ring terminals with terminal
screws (5).
b.
Apply electrical insulating compound to terminals
on horn switch. Install lug terminals (4) onto horn
switch.
NOTE
Wires for truck hitch (not used) are to be
insulated from each other and taped
together.
c.
Install ring terminals (3) onto switches. Install
lockwashers (2) and terminal screws (1) onto
switches using the jewelers screwdriver set.
Electrical insulating varnish fumes can be harmful if
inhaled. Use only in a well-ventilated area. Avoid
prolonged exposure to fumes. If personnel become dizzy
or drowsy during use, get immediate medical attention.
d.
Apply
electrical
insulating
varnish
to
ring
terminals (3).
NOTE
FOLLOW-ON-TASK: Install switch panel onto operator control console assembly per
paragraph 7.6.
END OF TASK
7-85