TM 5-3895-373-20B. INSTALL Continued.3.INSTALL LUG TERMINALS AND RINGTERMINALS ONTO SWITCH PANELCOMPONENTS.a.Install ring terminals (3) onto emergency stopswitch. Secure ring terminals with terminalscrews (5).b.Apply electrical insulating compound to terminalson horn switch. Install lug terminals (4) onto hornswitch.NOTEWires for truck hitch (not used) are to beinsulated from each other and tapedtogether.c.Install ring terminals (3) onto switches. Installlockwashers (2) and terminal screws (1) ontoswitches using the jeweler’s screwdriver set.Electrical insulating varnish fumes can be harmful ifinhaled. Use only in a well-ventilated area. Avoidprolonged exposure to fumes. If personnel become dizzyor drowsy during use, get immediate medical attention.d.Apply electrical insulating varnish to ringterminals (3).NOTEFOLLOW-ON-TASK: Install switch panel onto operator control console assembly perparagraph 7.6.END OF TASK7-85