TM 5-3895-373-20
7.6.
REPAIR/REPLACE OPERATOR CONTROL CONSOLE ASSEMBLY - Continued.
C.
INSTALL - Continued.
f.
Install circuit breaker (85) with button head
cap screws (86) onto relay mounting
bracket
(87).
Ensure
circuit
breaker
terminal (127) is aligned with terminal (100).
Tighten button head cap screws.
g.
Install wires 103 (84) and self-locking nut
(82) onto circuit breaker terminal (128).
Tighten nut.
h.
Install wire 142 (83) and self-locking nut
(82) onto circuit breaker terminal (127).
Tighten nut.
WARNING
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
i.
Apply electrical insulating varnish to all wire
connections.
GO TO NEXT PAGE
7-42