TM 5-3895-373-207.6. REPAIR/REPLACE OPERATOR CONTROL CONSOLE ASSEMBLY - Continued.B.CLEAN - Continued.WARNINGThread locking compound solventcan cause eye damage. Wear safetygoggles/ glasses when using. Avoidcontact with eyes. If solvent contactseyes, flush eyes with water and getimmediate medical attention.4.CLEAN HEX HEAD CAP SCREWS COATEDWITH THREAD LOCKING COMPOUND WITHTHREAD LOCKING COMPOUND SOLVENT.5.WIPE HEX HEAD CAP SCREWS DRY WITH ACLEAN, LINT-FREE CLOTH.C.INSTALL.1.INSTALL SLEEVE BUSHINGS INTOOPERATOR CONTROL CONSOLE.a.Place sleeve bushing (118) onto bushingpress tool (125).b.Position sleeve bushing (118) in shafthousing (126) on console frame (110).c.Tap on bushing press tool (125) with ahammer to install sleeve bushing (118)into shaft housing (126) until fully seated.d.Repeat procedure for second sleevebushing on other side of console frame(110).2.INSTALL CONSOLE SUPPORT ANGLESONTO OPERATOR CONTROL CONSOLE.a.Install console support angles (117 and116) onto console frame (110) and securewith button head cap screws (114) andhex nuts (115).b.Tighten hex nuts (115) to 9 lb-ft (12 N.m).GO TO NEXT PAGE7-38
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business