TM 5-3895-373-20C.INSTALL - Continued.7.INSTALL RELAY AND CIRCUIT BREAKERASSEMBLY AND ASSEMBLED RELAYMOUNTING BRACKET INTO OPERATORCONTROL CONSOLE.NOTEEnsure wires are routed throughconduit mounting flange as tagged.a.Place relay and circuit breaker assembly(81) and assembled relay mounting bracket(80) into operator control console (8).b.Install button head cap screws (79) throughoperator control console and intoassembled relay mounting bracket (80).Tighten to 9 lb-ft (12 N•m).c.Install button head cap screws (76) throughbottom of operator control console (8) andinto relay and circuit breaker assembly (81).d.Install flat washers (78) and hex nuts (77)onto button head cap screws (76). Tightenhex nuts to 9 lb-ft (12 N•m).GO TO NEXT PAGE7-43