TM 5-3895-373-20
C.
INSTALL - Continued.
7.
INSTALL RELAY AND CIRCUIT BREAKER
ASSEMBLY
AND
ASSEMBLED
RELAY
MOUNTING
BRACKET
INTO
OPERATOR
CONTROL CONSOLE.
NOTE
Ensure wires are routed through
conduit mounting flange as tagged.
a.
Place relay and circuit breaker assembly
(81) and assembled relay mounting bracket
(80) into operator control console (8).
b.
Install button head cap screws (79) through
operator
control
console
and
into
assembled relay mounting bracket (80).
Tighten to 9 lb-ft (12 Nm).
c.
Install button head cap screws (76) through
bottom of operator control console (8) and
into relay and circuit breaker assembly (81).
d.
Install flat washers (78) and hex nuts (77)
onto button head cap screws (76). Tighten
hex nuts to 9 lb-ft (12 Nm).
GO TO NEXT PAGE
7-43