TM 5-3895-373-20B.INSTALL - Continued.e.Install clamps (32) onto radiator overflowhose (33) and secure to radiator shroud(34) with hex head cap screws (29),lockwasher (30), and flat washer (31).Tighten cap screws to 37 Ib-ft (50 N•m).Thread locking compound solventcan cause eye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If solvent contactseyes, flush eyes with water and getimmediate medical attention.f.Clean threads of hex head cap screws (17and 20) with thread locking compoundsolvent.Thread locking compound can causeeye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If compoundcontacts eyes, flush eyes with waterand get immediate medical attention.g.Apply thread locking compound to threadsof socket head cap screws (26).h.Position mounting plates (27 and 28) per L(left) or R (right) markings on plates.i.Install mounting plates (27 and 28) andsocket head cap screws (26). Tighten capscrews using hex head driver socket to 37Ib-ft (50 N•m).j.Install flat washers (19 and 22) andlockwashers (18 and 21) onto hex headcap screws (17 and 20).k.Apply thread locking compound to threadsof hex head cap screws (17 and 20).l.Install spacers (25) and mounting brackets(23 and 24).m.Install hex head cap screws (17 and 20).Do not tighten cap screws at this time.GO TO NEXT PAGE6-5