TM 5-3895-373-20A.REMOVE.1.DISCONNECT TUBES AT MAIN SCREEDVIBRATION MOTOR.Cleaning solvent, PD680, is TOXIC andflammable. Wear protective goggles andgloves.Use only in a well ventilated area. Avoidcontact with skin, eyes, and clothes, anddo not breathe vapors. Keep away fromheat or flame. Never smoke when usingsolvent; the flashpoint for Type mcleaning solvent is 200°F (93,30C).Failure to do so may result in injury ordeath to personnel.If personnel become dizzy while usingcleaning solvent, immediately get fresh airand medical help. If solvent contacts skinor clothes, flush with cold water. Ifsolvent contacts eyes, flush eyes withwater and get immediate medicalattention.Thoroughly clean hydraulic hoses andfittings before disconnecting. Alwaysplug or cap off disconnected fittings toprevent intrusion of contaminants.Failure to properly clean and cap offconnectors may result in hydraulic systemcontamination and equipment damage.a.Use cleaning solvent and cleaning cloth toclean around hydraulic fittings at main screedvibration WARNING motor (1).b.Place machinery wiping towel below hydraulicfittings vibration motor.Hydraulic oil can be moderatelyflammable and on main screed can be anirritant to the skin, eyes, and respiratorysystem. Avoid prolonged exposure. Eyeprotection and rubber gloves must beworn when working with hydraulic oil.c.Tag and disconnect tubes (2 and 3) fromelbows (4). Plug tubes and elbows. Discardmachinery wiping towel in accordance withlocal procedures.GO TO NEXT PAGE15-87