TM 5-3895-373-10
2.14.3
Feed Limit Switch Paddle Adjustment.
NOTE
Feed limit switch paddle adjustment
is the same for left and right paddles.
a.
To increase the amount of material allowed to
accumulate in auger chamber during automatic
auger/ conveyor system operation, use the
following procedure.
(1)
Loosen hex nut.
(2)
Loosen thumbscrew.
(3)
Slide feed limit switch paddle upward to
the depth desired.
(4)
Tighten thumbscrew and hex nut.
b.
To decrease the amount of material allowed to
accumulate in auger chamber during automatic
auger/ conveyor system operation, use the
following procedure.
(1)
Loosen hex nut.
(2)
Loosen thumbscrew.
(3)
Slide feed limit switch paddle downward to
the depth desired.
(4)
Tighten thumbscrew and hex nut.
2.15
FLOW GATE OPERATION.
NOTE
Flow gate switches are located on
both the switch panel and screed
control panel. The flow gate switches
on the left and right screed control
panels control flow gates on each
side respectively.
a.
To change flow gate position, hold the flow gate
switch in the up position to increase flow or in the
down position to decrease flow.
b.
When the flow gate reaches the desired
position, release the flow gate switch. The
switch will spring return to the center neutral
position.
2.16
SCREED BURNER OPERATION.
a.
Start paving machine per paragraph 2.10.
b.
Set the throttle control switch to left, MAX.
c.
Raise screed per paragraph 2.1.2.
d.
Extend left and right screed extensions fully
open using extension screed control switches on
left and right screed control panels or on switch
panel per 2.19.
e.
Lower screed per paragraph 2.1.2.
2-40