TM 5-3895-373-102.14.3FeedLimitSwitchPaddleAdjustment.NOTEFeed limit switch paddle adjustmentis the same for left and right paddles.a.To increase the amount of material allowed toaccumulate in auger chamber during automaticauger/ conveyor system operation, use thefollowing procedure.(1)Loosen hex nut.(2)Loosen thumbscrew.(3)Slide feed limit switch paddle upward tothe depth desired.(4)Tighten thumbscrew and hex nut.b.To decrease the amount of material allowed toaccumulate in auger chamber during automaticauger/ conveyor system operation, use thefollowing procedure.(1)Loosen hex nut.(2)Loosen thumbscrew.(3)Slide feed limit switch paddle downward tothe depth desired.(4)Tighten thumbscrew and hex nut.2.15FLOWGATEOPERATION.NOTEFlow gate switches are located onboth the switch panel and screedcontrol panel. The flow gate switcheson the left and right screed controlpanels control flow gates on eachside respectively.a.To change flow gate position, hold the flow gateswitch in the up position to increase flow or in thedown position to decrease flow.b.When the flow gate reaches the desiredposition, release the flow gate switch. Theswitch will spring return to the center neutralposition.2.16SCREEDBURNEROPERATION.a.Start paving machine per paragraph 2.10.b.Set the throttle control switch to left, MAX.c.Raise screed per paragraph 2.1.2.d.Extend left and right screed extensions fullyopen using extension screed control switches onleft and right screed control panels or on switchpanel per 2.19.e.Lower screed per paragraph 2.1.2.2-40