TM 5-3895-373-103.2. TROUBLESHOOTING.Table 3-1. Troubleshooting Table - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION1. ENGINE WILL NOT CRANK.Step 1. Check control handle position.Place both control handles in the center, neutral, position per paragraph 2.1.1.Step 2. Check position of emergency stop switches.Pull out all three emergency stop switches per paragraph 2.1.2 and 2.2.1.Step 3. Check position of CB1.Reset CB 1. If CB 1I trips a second time, inform supervisor.2. ENGINE CRANKS BUT WILL NOT START.Step 1. Turn ignition switch to the preheat position per paragraph 2.1.1. Check for voltage drop on thevoltmeter when the induction heater comes on.Inform supervisor if voltage does not change.Step 2. Check for smoke from the exhaust system when cranking engine.If smoke from the exhaust is white, check fuel tank level and refill as necessary per paragraph3.3.3. If smoke from the exhaust system is black, check the air cleaner. If the air cleaner filterelement is dirty or clogged, replace the element per paragraph 3.3.6. If fuel level and aircleaner filter element are OK, inform supervisor of problem.3. ENGINE OIL PRESSURE LOW. Refer to Table 3-2.Shut down the engine and check engine oil level.If engine oil level is low, add engine oil as necessary per paragraph 3.3.2. If engine oil level isOK, inform supervisor of problem.3-3