TM 5-3895-373-10
Table 3-1. Troubleshooting Table - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
11. AUGER/CONVEYOR SYSTEMS WILL NOT OPERATE.
Step 1. Check hydraulic reservoir level.
If hydraulic oil level is low, add hydraulic oil as necessary per paragraph 3.3.4.
Step 2. Check auger/conveyor speed control valve settings.
If auger/conveyor speed control valves are closed (fully clockwise), open valves to increase
auger/conveyor speeds per paragraph 2.1.3.
Step 3. Check the position of the feeder control switches.
Place the feed control switches in the up, ON, position per paragraph 2.2.1.
Step 4. Check the feed limit switch paddle for free movement.
Free feed limit switch paddle by removing any obstructions.
Step 5. Check position of CB6.
Reset CB6. If CB6 trips a second time, inform supervisor.
Step 6. If hydraulic oil level, speed control valve settings, feed control switch settings, feed limit switch
paddles, and circuit breaker CB6 are OK, inform supervisor of problem.
3-6