TM 5-3895-373-10Table 3-1. Troubleshooting Table - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION12. ONE AUGER/CONVEYOR SYSTEM WILL NOT OPERATE.Step 1. Check auger/conveyor speed control valve setting.If auger/conveyor speed control valve is closed (fully clockwise), open valve to increaseauger/conveyor speed per paragraph 2.1.3.Step 2. Check the position of the feeder control switches.Place the feeder control switches in the up, ON, position per paragraph 2.2.1.Step 3. Check for jamming of the conveyor.Attempt to move the conveyor in the reverse direction per paragraph 2.2.1. If the conveyormoves in the reverse direction, jog the conveyor forward and reverse to free the jam. Ifconveyor will not move in reverse and jamming is still suspected, use fuel spray washdownsystem to dissolve any hardened asphalt per paragraph 3.3.7.Step 4. If speed control valve and feeder control switch settings are OK and conveyor is not jammed, informsupervisor of problem.13. AUGER/CONVEYOR SYSTEM RUNS SLOWLY.Step 1. Check hydraulic reservoir level.If hydraulic oil level is low, add hydraulic oil as necessary per paragraph 3.3.4.Step 2. Check position of the auger/conveyor speed control valve.Turn the speed control knob counterclockwise to increase speed.Step 3. If hydraulic oil level and auger/conveyor speed control valve setting are OK, inform supervisor ofproblem.3-7