Table 2-2. Troubleshooting (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9. SPRAY LACKS PRESSURE (Continued):
Discharge strainer plugged.
step 3.
10. APPLICATION RATE VARIES:
Improper reading of tank contents.
Step 1.
Use measuring stick for accurate readings. Tank must be level when reading
measuring stick.
Step 2.
Defective recording bitumeter.
step 3.
Catch lever on quadrant not pulled.
step 4.
Pull catch lever out.
Discharge strainer plugged.
step 5.
Remove and clean discharge strainer on pump outlet (para 12-6).
Hydrostatic control not firmly positioned.
Step 6.
Adjust and tighten (TM 5-3895-371-10).
Hydrostatic override control partially engaged.
step 7.
Return override to neutral position.
11. DIFFICULTY IN RAISING SPRAY BAR END SECTIONS IN VERTICAL POSITIONS:
Hinge joint inoperative.
step 1.
step 2.
Damaged linkage