TM 5-3895-371-24 & P
Table 2-1. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES
(Continued)
A-Annually
S-Semiannually
B-Biennially
Q-Quarterly
H-Hours
M-Miles
INTERVAL
ITEM TO BE INSPECTED
ITEM
NO.
Q
S
A
B
H
Ml
PROCEDURE: Check for and have repaired, filled, or adjusted
as needed.
BURNER FUEL SYSTEM (Continued)
Check smoke stack cover spring for damage and check operation.
11
Replace spring if necessary.
BITUMETER WHEEL ASSEMBLY
Check air lines and fittings. If damaged, replace.
12
Check power line and ground on solenoid for corrosion and bare
13
wires, replace defective wires.
Check that bitumeter positions itself when activated. Adjust or
14
repair as needed.
SPRAY BAR
Check that spray bar positions itself whenever control switches are
15
activated. Adjust as needed.
Check chains. Replace as necessary.
16
Check power lines to solenoids for corrosion and bare wires. Replace
17
defective wires.
Check relation of quadrant lever position with nozzle lever position.
18
Adjust linkage as needed.
Check recording bitumeter cable operation and service it.
19
20
Check air control reservoir. Open drain cock to let out condensation.
21
2-5