Air in oil
See Paragraph 3
Charge pump malfunction
Charge pump pressure should be at
Replace as necessary
9
1 thru 3
least 25 psi per 1000 psi working
pressure with normal case drain flows.
See Paragraph 4.
Figure 104
88