Figure 3. Propel Switch Function Status Window.
ure 4. Left Keypads Switch Function Status Window.

Field Maintenance Manual For Bituminous Material Paving Machine - 3 Page Navigation
  82    83    84    85    86  87  88    89    90    91    92  
img
.
TM 5-3895-385-23-3
0444
Switch Function Status Joy Stick
1. Select PROPEL from Plus One Diagnostic Navigator window (Figure 3, Item 1). Switch function Graphical
Overview window (Figure 3, Item 2) will display.
NOTE
Switch function status defaults to OFF (red) until a push-button switch is selected. Once a push-
button switch has been selected, the corresponding status box will display ON (green) if the
selected push-button switch is functioning properly.
2. Move left joystick (Figure 2, Item 6) from neutral position. Verify "LtNeutralSW" status box on Plus One
Graphical Overview window (Figure 3, Item 2) displays ON (green). Refer to Table 1 for status box
identification.
3. Move right joystick (Figure 2, Item 5) from neutral position. Verify "RtNeutralSW" status box on Plus One
Graphical Overview window (Figure 3, Item 2) displays ON (green). Refer to Table 1 for status box
identification.
NOTE
If corresponding status box does not display ON (green), refer to WP 0004, Vol 1.
END OF TASK
0444-5