Hydraulic Generator Removal
CAUTION
Tag and label hydraulic hoses prior to removal. Hydraulic hoses must be installed correctly for
proper operation. Failure to comply may cause damage to equipment.
1. Disconnect hydraulic hose 115 (Figure 1, Item 5), hydraulic hose 118 (Figure 1, Item 6), hydraulic hose 116
(Figure 1, Item 7), and hydraulic hose 117 (Figure 1, Item 8) from hydraulic generator hydraulic fittings, and
cap/plug hydraulic hoses and hydraulic fittings.
2. Remove bolt (Figure 1, Item 4) from hydraulic generator (Figure 1, Item 2) and wiring bracket (Figure 1, Item
3).
3. Remove three bolts (Figure 1, Item 9), and remove hydraulic generator top cover (Figure 1, Item 1).