Figure 1. Variable Auger Pump.
VARIABLE AUGER PUMP REMOVAL AND INSTALLATION - Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  543    544    545    546    547  548  549    550    551    552    553  
img
.
TM 5-3895-385-23-2
0319
Variable Auger Pump Removal -- Continued.
WARNING
The variable auger pump weighs 158 pounds (lb) (71.7 kilograms (kg)). Use a suitable lifting
device. Failure to comply may cause injury or death to personnel.
CAUTION
Properly support the item being lifted. Failure to comply may cause damage to equipment.
1. Remove two bolts (Figure 1, Item 4), lock washers (Figure 1, Item 5), O-ring (Figure 1, Item 2), and variable
auger pump (Figure 1, Item 3) from double hydraulic pump (Figure 1, Item1) with assistance. Discard lock
washers and O-ring.
NOTE
Note orientation of fittings for reinstallation.
2. Remove fittings from variable auger pump (Figure 1, Item 3).
END OF TASK
Variable Auger Pump Installation
WARNING
The variable auger pump weighs 158 lb (71.7 kg). Use a suitable lifting device. Failure to comply
may cause injury or death to personnel.
CAUTION
Properly support the item being lifted. Failure to comply may cause damage to equipment.
1. Install fittings onto variable auger pump (Figure 1, Item 3) as noted in removal.
2. Install two bolts (Figure 1, Item 4), new lock washers (Figure 1, Item 5), new O-ring (Figure 1, Item 2), and
variable auger pump (Figure 1, Item 3) onto double hydraulic pump (Figure 1, Item1) with assistance.
END OF TASK