Figure 9. Relay Block.
Figure 11. Transformer.

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  330    331    332    333    334  335  336    337    338    339    340  
img
.
TM 5-3895-385-23-2
0277
Fuse Box Disassembly -- Continued.
Figure 10. Terminal Block.
CAUTION
Tag and label electrical wires prior to removal. Electrical wires must be installed correctly for
proper operation. Failure to comply may cause damage to equipment.
14. Remove 14 screws (Figure 10, Item 4) and wires (Figure 10, Item 2) from terminal block (Figure 10, Item 3)
connectors.
15. Remove two nuts (Figure 10, Item 8), lock washers (Figure 10, Item 7), flat washers (Figure 10, Item 6),
screws (Figure 10, Item 5), and terminal block (Figure 10, Item 3) from fuse box panel (Figure 10, Item 1).
Discard lock washers.
0277-12