Figure 8. Relay
Figure 10. Terminal Block.

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  329    330    331    332    333  334  335    336    337    338    339  
img
.
TM 5-3895-385-23-2
0277
Fuse Box Disassembly -- Continued.
Figure 9. Relay Block.
11. Remove nut (Figure 9, Item 1), lock washer (Figure 9, Item 2), flat washer (Figure 9, Item 5), screw (Figure 9,
Item 6), and relay block (Figure 9, Item 4) from fuse box panel (Figure 9, Item 3). Discard lock washer.
12. Remove retaining tab (Figure 9, Item 7) from relay block (Figure 9, Item 4).
CAUTION
Tag and label electrical wires prior to removal. Electrical wires must be installed correctly for
proper operation. Failure to comply may cause damage to equipment.
13. Remove four wires (Figure 9, Item 8) from relay block (Figure 9, Item 4) connectors.
0277-11