RUN/STOP TOGGLE SWITCH REMOVAL AND INSTALLATION
RUN/STOP TOGGLE SWITCH REMOVAL AND INSTALLATION - Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  265    266    267    268    269  270  271    272    273    274    275  
img
.
TM 5-3895-385-23-2
0265
RUN/STOP TOGGLE SWITCH REMOVAL AND INSTALLATION
Run/Stop Toggle Switch Removal
Figure 1. Run/Stop Toggle Switch.
1. Disconnect two wires (Figure 1, Item 3) from run/stop toggle switch (Figure 1, Item 2) connector.
2. Remove dust boot (Figure 1, Item 1) from run/stop toggle switch (Figure 1, Item 2).
3. Remove run/stop toggle switch (Figure 1, Item 2) from pedestal assembly.
END OF TASK
Run/Stop Toggle Switch Installation
1. Install run/stop toggle switch (Figure 1, Item 2) into pedestal assembly.
2. Install dust boot (Figure 1, Item 1) onto run/stop toggle switch (Figure 1, Item 2).
3. Connect two wires (Figure 1, Item 3) to run/stop toggle switch (Figure 1, Item 2) connector.
END OF TASK