Figure 1. EMERGENCY STOP Switch.
RUN/STOP TOGGLE SWITCH REMOVAL AND INSTALLATION

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  263    264    265    266    267  268  269    270    271    272    273  
img
. .
TM 5-3895-385-23-2
0264
EMERGENCY STOP Switch Installation
1. Connect cables (Figure 1, Item 4) to EMERGENCY STOP switch control box (Figure 1, Item 5), and tighten
screws (Figure 1, Item 3).
2. Install EMERGENCY STOP switch (Figure 1, Item 1) into pedestal assembly.
3. Install nut (Figure 1, Item 6) and spacer (Figure 1, Item 7) onto EMERGENCY STOP switch (Figure 1, Item
1).
4. Install EMERGENCY STOP switch control box (Figure 1, Item 5) to EMERGENCY STOP switch (Figure 1,
Item 1).
END OF TASK
FOLLOW-ON TASK
1. Install platform control (WP 0262).
2. Verify proper operation.
END OF TASK
END OF WORK PACKAGE