TM 5-3895-385-23-1
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
LEFT PLATFORM CONTROL DISPLAY MALFUNCTION
INITIAL SETUP:
Test Equipment
References
WP 0373, Vol 2
Personnel Required
WP 0374, Vol 2
91L
WP 0386, Vol 2
Assistant
WP 0399, Vol 2
References
WP 0443, Vol 3
WP 0447, Vol 3
WP 0263, Vol 2
WP 0451, Vol 3
WP 0277, Vol 2
Equipment Conditions
Engine off (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Left Control Pedestal Display Malfunction Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. No power to display.
1. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check to see if the left control
1. If left control pedestal display
pedestal display displays
does not display anything,
anything.
proceed to next malfunction.
2. If left control pedestal display
displays anything, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to malfunction 8.
2. Fuse box malfunction.
Check to see if the right control
1. If right control pedestal display
pedestal display displays anything.
does not display anything, turn
keyless engine switch to the
OFF position (TM 5-3895-385-