TM 5-3895-385-23-1
0208
Table 1. Left Run/Stop Toggle Switch Malfunction Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If no continuity is present,
proceed to next malfunction.
2. Main wiring harness has an
1. Disconnect W1 J31 connector
open circuit.
(WP 0451, Vol 3, Figure 6).
1. If continuity is present, proceed
0443, Vol 3) between main
to next malfunction.
wiring harness W1 J2 Pin 10 and
W1 J31 Pin 3 (WP 0451, Vol 3,
Figures 2 and 6).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
3. Left pedestal wiring harness
1. Access platform control (WP
has an open circuit.
0262, Vol 2).
2. Ensure run/stop toggle switch is
in the RUN position (TM 5-3895-
385-10).
1. If continuity is present, replace
0443, Vol 3) across run/stop
left pedestal wiring harness (WP
toggle switch posts one and two
0374, Vol 2).
(WP 0447, Vol 3, Figure 19).
2. If no continuity is present,
replace run/stop toggle switch
(WP 0265, Vol 2).
END OF WORK PACKAGE
0208-2