Table 1. Left Control Pedestal Display Malfunction Troubleshooting Procedures -- Continued
Table 1. Left Control Pedestal Display Malfunction Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  1018    1019    1020    1021    1022  1023  1024    1025    1026    1027    1028  
img
TM 5-3895-385-23-1
0211
Table 1. Left Control Pedestal Display Malfunction Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) from C13 J1 pin B
to next test.
to C13 J2 pin B (WP 0451, Vol
3, Figures 49 and 50).
2. If no continuity is present,
replace damaged
communication cable (WP 0386,
Vol 2).
5. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) from C13 J1 pin C
to next malfunction.
to C13 J2 pin C (WP 0451, Vol
3, Figures 49 and 50).
2. If no continuity is present,
replace damaged
communication cable (WP 0386,
Vol 2).
13.Communication cable C13 has
1. Measure for continuity (WP
1. If continuity is present, replace
short circuit.
0443, Vol 3) from C13 J1 pin A
damaged communication cable
to every other pin on C13 J1
(WP 0386, Vol 2).
(WP 0451, Vol 3, Figures 49 and
50).
2. If no continuity is present,
proceed to next test.
2. Measure for continuity (WP
1. If continuity is present, replace
0443, Vol 3) from C13 J1 pin B
damaged communication cable
to every other pin on C13 J1
(WP 0386, Vol 2).
(WP 0451, Vol 3, Figures 49 and
50).
2. If no continuity is present,
proceed to next test.
3. Measure for continuity (WP
1. If continuity is present, replace
0443, Vol 3) from C13 J1 pin C
damaged communication cable
to every other pin on C13 J1
(WP 0386, Vol 2).
(WP 0451, Vol 3, Figures 49 and
50).
2. If no continuity is present,
proceed to next malfunction.