TM 5-3895-385-23-1
0207
Table 1. Right Run/Stop Toggle Switch Malfunction Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If no continuity is present,
proceed to next malfunction.
2. Main wiring harness has an
1. Disconnect W1 J32 from wiring
open circuit.
harness (WP 0451, Vol 3, Figure
2).
1. If continuity is present, proceed
0443, Vol 3) between main
to next malfunction.
wiring harness W1 J2 Pin 6 and
W1 J32 Pin 3 (WP 0451, Vol 3,
Figures 2 and 6).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
3. Right pedestal wiring harness
1. Access platform control (WP
has an open circuit.
0262, Vol 2).
2. Ensure run/stop toggle switch is
in the RUN position (TM 5-3895-
385-10).
1. If continuity is present, replace
0443, Vol 3) across run/stop
right pedestal wiring harness
toggle switch posts (WP 0447,
(WP 0375, Vol 2).
Vol 3, Figure 19).
2. If no continuity is present,
replace run/stop toggle switch
(WP 0265, Vol 2).
END OF WORK PACKAGE
0207-2