Table 1. Right Console Left Joy Cal Fault Troubleshooting Procedures -- Continued
Table 1. Right Console Right Joy Cal Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  972    973    974    975    976  977  978    979    980    981    982  
img
. . . . . .
TM 5-3895-385-23-1
0196
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
RIGHT CONSOLE RIGHT JOY CAL FAULT
INITIAL SETUP:
Test Equipment
References
Multimeter (WP 0440, Vol 3, Item 37)
WP 0180
Personnel Required
WP 0194
91L
WP 0267, Vol 2
Assistant
WP 0399, Vol 2
Equipment Conditions
Engine off (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Right Console Right Joy Cal Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Turn keyless engine switch to
screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check fault screen for PROPEL
1. If fault is found, turn keyless
CONTROLLER OFFLINE fault.
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to WP 0180.
2. If no fault is found, proceed to
next test.
3. Check fault screen for RIGHT
1. If fault is found, turn keyless
CONSOLE RIGHT JOY fault.
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to WP 0194.
2. If no fault is found, proceed to
next malfunction.
2. Joystick out of calibration.
1. Perform joystick calibration
procedure to right control
pedestal joysticks (WP 0267, Vol
2).