RIGHT CONSOLE LEFT JOY CAL FAULT
RIGHT CONSOLE RIGHT JOY CAL FAULT

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  971    972    973    974    975  976  977    978    979    980    981  
img
TM 5-3895-385-23-1
0195
Table 1. Right Console Left Joy Cal Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Attempt to drive Bituminous
1. If fault is still active, replace
Material Paving Machine
joystick (WP 0267, Vol 2),
(BMPM), and verify that RIGHT
attempt to drive BMPM, and
CONLOLE LEFT JOY CAL fault
verify that RIGHT CONSOLE
is no longer active.
LEFT JOY CAL fault is no
longer active.
2. If fault is no longer active, the
problem is resolved.
3. If fault is still active after
replacing joystick, replace
propel controller module
Electronic Control Module
(ECM) (WP 0399, Vol 2).
4. If fault is no longer active after
replacing joystick, the problem
is resolved.
END OF WORK PACKAGE