TM 5-3895-385-23-1
0182
Table 1. Output Module Offline Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If no continuity is present,
replace damaged
communication cable (WP 0386,
Vol 2).
1. If continuity is present, proceed
0443, Vol 3) from C9 J1 pin C to
to next malfunction.
C9 J2 pin C (WP 0451, Vol 3,
Figure 51).
2. If no continuity is present,
replace damaged
communication cable (WP 0386,
Vol 2).
11.Communication cable C9 has
1. If continuity is present, replace
short circuit.
0443, Vol 3) from C9 J1 pin A to
damaged communication cable
every other pin on C9 J1 (WP
(WP 0386, Vol 2).
0451, Vol 3, Figure 51).
2. If no continuity is present,
proceed to next test.
1. If continuity is present, replace
0443, Vol 3) from C9 J1 pin B to
damaged communication cable
every other pin on C9 J1 (WP
(WP 0386, Vol 2).
0451, Vol 3, Figure 51).
2. If no continuity is present,
proceed to next test.
1. If continuity is present, replace
0443, Vol 3) from C9 J1 pin C to
damaged communication cable
every other pin on C9 J1 (WP
(WP 0386, Vol 2).
0451, Vol 3, Figure 51).
2. If no continuity is present,
proceed to next malfunction.
12. Screed controller (ECM) has
1. Disconnect main wiring harness
damage or loose pin.
W1 J1 from screed controller
module ECM (WP 0451, Vol 3,
Figure 1).
2. Check screed controller module
1. If screed controller module ECM
ECM for damage or loose pin.
has damage or loose pin,
replace screed controller module
ECM (WP 0399, Vol 2).
0182-7