Table 1. Output Module Offline Fault Troubleshooting Procedures -- Continued
Table 1. Output Module Offline Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  742    743    744    745    746  747  748    749    750    751    752  
img
TM 5-3895-385-23-1
0182
Table 1. Output Module Offline Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
17. Main wiring harness has a short
1. Measure for continuity (WP
1. If continuity is present, replace
circuit.
0443, Vol 3) between main
main hydraulic manifold wiring
wiring harness W1 J39 Pin 3 and
harness (WP 0373, Vol 2).
all other pins on the main wiring
harness W1 J39 (WP 0451, Vol
3, Figure 1).
2. If no continuity is present,
proceed to next test.
2. Measure for continuity (WP
1. If continuity is present, replace
0443, Vol 3) between main
main hydraulic manifold wiring
wiring harness W1 J39 Pin 4 and
harness (WP 0373, Vol 2).
all other pins on the main wiring
harness W1 J39 (WP 0451, Vol
3, Figure 1).
2. If no continuity is present,
proceed to next test.
3. Measure for continuity (WP
1. If continuity is present, replace
0443, Vol 3) between main
main hydraulic manifold wiring
wiring harness W1 J39 Pin 5 and
harness (WP 0373, Vol 2).
all other pins on the main wiring
harness W1 J39 (WP 0451, Vol
3, Figure 1).
2. If no continuity is present,
proceed to next malfunction.
18.Communication connector Y10
1. Measure for continuity (WP
1. If continuity is present, proceed
has an open circuit.
0443, Vol 3) between
to next test.
communication connector Y10
P1 Pin A and Y10 P2 Pin A (WP
0451, Vol 3, Figure 51).
2. If no continuity is present,
replace communication
connector Y10 (WP 0386, Vol 2).
2. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) between
to next test.
communication connector Y10
P1 Pin A and Y10 P3 Pin A (WP
0451, Vol 3, Figure 51).
2. If no continuity is present,
replace communication
connector Y10 (WP 0386, Vol 2).