TM 5-3895-385-23-1
0180
Table 1. Propel Controller Offline Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. If continuity is present, replace
0443, Vol 3) between main
main hydraulic manifold wiring
wiring harness W1 J1 Pin 4 and
harness (WP 0373, Vol 2).
all other pins on the main wiring
harness W1 J1 (WP 0451, Vol 3,
Figure 1).
2. If no continuity is present,
proceed to next test.
1. If continuity is present, replace
0443, Vol 3) between main
main hydraulic manifold wiring
wiring harness W1 J1 Pin 5 and
harness (WP 0373, Vol 2).
all other pins on the main wiring
harness W1 J1 (WP 0451, Vol 3,
Figure 1).
2. If no continuity is present,
proceed to next malfunction.
13. Main wiring harness has an
1. If continuity is present, proceed
open circuit.
0443, Vol 3) between main
to next test.
wiring harness W1 J2 Pin 3 and
main wiring harness W1 J28 Pin
A (WP 0451, Vol 3, Figure 2).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
1. If continuity is present, proceed
0443, Vol 3) between main
to next test.
wiring harness W1 J2 Pin 4 and
main wiring harness W1 J28 Pin
B (WP 0451, Vol 3, Figure 2).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
1. If continuity is present, proceed
0443, Vol 3) between main
to next malfunction.
wiring harness W1 J2 Pin 5 and
main wiring harness W1 J28 Pin
C (WP 0451, Vol 3, Figure 2).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
0180-8