Table 1. Right Auger Bypass Malfunction Troubleshooting Procedures -- Continued
Table 1. Left Auger Bypass Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  692    693    694    695    696  697  698    699    700    701    702  
img
. . . . .
TM 5-3895-385-23-1
0174
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
LEFT AUGER BYPASS FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0373, Vol 2
Personnel Required
WP 0377, Vol 2
91L
WP 0399, Vol 2
Assistant
WP 0443, Vol 3
References
WP 0451, Vol 3
WP 0180
Equipment Conditions
WP 0316, Vol 2
Engine off (TM 5-3895-385-10)
Hydraulic oil cool (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Left Auger Bypass Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Turn keyless engine switch to
screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check fault screen for PROPEL
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0180.
2. If no fault is found, proceed to
next malfunction.
2. Hydraulic solenoid malfunction.
1. Disconnect bulkhead wiring
harness W11 J3 from left auger
bypass hydraulic solenoid (WP
0451, Vol 3, Figure 29).
2. Turn auger conveyor to full
speed in manual mode (TM 5-
3895-385-10).