Table 1. Beacon Relay Fault Troubleshooting Procedures -- Continued
HYD TEMP SENSOR FAULT

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  680    681    682    683    684  685  686    687    688    689    690  
img
. . . . . . . .
TM 5-3895-385-23-1
0167
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
HYDRAULIC OIL TEMPERATURE SENSOR MALFUNCTION
INITIAL SETUP:
Personnel Required
Equipment Conditions
91L
Engine off (TM 5-3895-385-10)
References
Hydraulic oil cool (TM 5-3895-385-10)
WP 0168
WP 0180
WP 0305, Vol 2
TROUBLESHOOTING PROCEDURES
Table 1. Hydraulic Oil Temperature Sensor Malfunction Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Turn keyless engine switch to
screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check fault screen for PROPEL
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0180.
2. If no fault is found, proceed to
next test.
3. Check fault screen for HYD
1. If fault is found, proceed to WP
TEMP SENSOR fault.
0168.
2. If no fault is found, replace
hydraulic oil temperature sensor
(WP 0305, Vol 2).
END OF WORK PACKAGE
0167-1/2 blank