TM 5-3895-385-23-1
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
BEACON RELAY FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
WP 0373, Vol 2
Personnel Required
WP 0399, Vol 2
91L
WP 0443, Vol 3
Assistant
WP 0447, Vol 3
References
WP 0451, Vol 3
Equipment Conditions
WP 0277, Vol 2
Engine off (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Beacon Relay Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Screed Controller Offline fault
1. Start Bituminous Material Paving
indicated on fault screen.
Machine (BMPM) engine (TM 5-
3895-385-10).
2. Attempt to turn on beacon light
using keypad (TM 5-3895-385-
10).
3. Check fault screen for SCREED
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
2. If no fault is found, proceed to
next malfunction.
1. Access fuse box (WP 0277, Vol
2).
2. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine.
3. Turn on beacon using control
pedestal beacon keypad (TM 5-
3895-385-10).