TM 5-3895-385-23-1
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
RIGHT CONVEYOR FAILS TO TURN
INITIAL SETUP:
Personnel Required
References -- Continued
91L
Assistant
References
WP 0298, Vol 2
WP 0300, Vol 2
WP 0316, Vol 2
WP 0415, Vol 2
WP 0416, Vol 2
WP 0417, Vol 2
WP 0419, Vol 2
WP 0446, Vol 3
Equipment Conditions
Engine off (TM 5-3895-385-10)
Hydraulic oil cool (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Right Conveyor Fails to Turn Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Start Bituminous Material Paving
screen.
Machine (BMPM) engine (TM 5-
3895-385-10).
2. Attempt to turn on left conveyor
using keypad (TM 5-3895-385-
10).
3. Check fault screen for SCREED
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
2. If no fault is found, proceed to
next test.